home distributors support information
SEARCH | CONTACT US | SECURE SITE

Autosamplers

Access this page in .pdf format & Get Adobe Acrobat[TM] Reader

Variable-volume Autosampler

The variable-volume autosampler provides outstanding performance and maximum flexibility in a variable-volume, LC sample processing system. The standard unit provides 120-vial capacity, multiple injection modes, random vial access, reuse of calibration standards, and nonvolatile storage of 4 complete methods.

Inert Autosampler

The inert autosampler provides all the features of the variable-volume autosampler, but in a metal-free, inert version. This autosampler is ideally suited for biological applications requiring metal-free operation or applications that use corrosive solvents or buffers.

Fixed-loop Autosampler

The fixed-loop autosampler is designed especially for those laboratories that process large numbers of samples on a routine basis. Injection volume can be varied simply by changing the sample loop. The standard unit allows 120 vials, multiple methods, and reuse of calibration standards.

Integrated Options

Column Oven

Provides complete control of the column and injector temperature to stabilize your separations for trouble-free overnight operation. Available on all models.

Sample Prep

Outstanding dilution performance, a unique vortex mixer and vial heater, and a flexible, easy-to-use sample preparation language provide unmatched versatility and capability. Available on the Variable-volume and Inert models.

Peltier Cooling

Sample temperature control is completely self-contained and fully integrated with your LC system. There are no external parts, connections, or water baths. Available on the Variable-volume and Inert models.

Vial Capacity 120 vials in 3 removable trays;
105 vials in the cooled models
Variable Volume  
Injection Precision <0.5% RSD @5 µL
Injection Volume 0.1 - 100 µL injections standard
(250 µL syringe);
up to 1500 µL injections with
larger loops and syringe
Fixed Loop  
Injection Precision <0.5% RSD @10 µL or greater
Injection Volume 20 µL loop standard
(250 µL syringe);
up to 500 µL injections with
larger loops and syringe
Sample Carryover <0.01% at 300 µL flush volume; up
to 5 mL flush volumes can be set
Minimum Sample Volume 1 µL can be injected from 5 µL,
using a microvial and needle height
adjustment; sample waste <2 µL
Needle Height Programmable in 0.1 mm
increments
Column Oven (optional) Settable in 1º C increments from 20
- 80º C, starting at 5º C above
ambient; temperature stability ±0.2º
C; accommodates up to 30 cm
columns
Sample Cooling (optional) Integrated peltier cooling, settable in
1º C increments from 0 - 30º C
Sample Preparation (optional)  
Reagent Vials Up to 3 vials can be specified
per file
Dilution Solvents Up to 4 external solvents can be
selected
Mixing/Heating Single vial, air-driven vortex
mixer/heater, settable in 1º C
increments from 30 - 100º C
Dilution Precision Typically <1.0% RSD for a
1/100 dilution (10 µL to 1 mL),
for the combined dilution and
injection
Dispensing Precision Typically <0.2% RSD for 1 mL
dispensing from external solvent
reservoir
Method Files Protected in nonvolatile memory
Communications  
Remote Inputs Pump Ready
Inject hold
Outputs Pump Stop, Autosampler Ready,
Gradient Start, Inject
4 timed event outputs
RS-232
Ambient Environment 10 - 40º C, 5 - 95% relative
humidity, noncondensing
Dimensions 14.5" (37 cm) H
16" (41 cm) W
19.75" (51 cm) D
Weight 35.2 lbs. (16 kg) standard;
52.8 lbs. (24 kg) with all options
installed
Power 100/120/220/240 Vac nominal
80-450 VA, depending on installed
options;
50/60 Hz
Product Certification CSA, TUV/GS
FCC (EMI)
VDE (EMI) applied for

RETURN TO TOP OF THE PAGE


(c) 1999-2006  ALL RIGHTS RESERVED.
349 N. Science Park Road - State College, PA 16803 - USA
Toll Free: 800-441-4752 - Tel: 814-234-7317 - Fax: 814-238-6072

Please see our Warranty & Return Policy

Site Supervision: IT Department