PhotoDiode Array Detector Model 6000

5 times the sensitivity of any other PDA detector.
& ![]()
DOWNLOAD A POWERPOINT PRESENTATION ON THE DA 6000
CHROMQUEST SPECTRAL ANALYSIS SOFTWARE
| Photodiode
array detection system with breakthrough proprietary
LightPipe technology The proprietary Model 6000 LightPipe
flow cell is the most important advance since photodiode
array technology was introduced in the 1980s. The
LightPipe is the heart of a detection system that meets
the most demanding requirements for sensitivity,
performance, accuracy, and precision. Unmatched sensitivity and performance The Model 6000 s LightPipe 50 mm flow cell is five times the industry standard length, yet no light is lost, due to its special interior surface. Flow cell volume is only 2 µL per 10 mm for sharper, higher peaks which greatly increase sensitivity. Deuterium and tungsten-halogen lamps intensify the light level across the 190 nm to 800 nm spectral range, limiting baseline noise for greater sensitivity at longer wavelengths. Performance A 20 Hz high-speed diode array allows faster collection of data, permitting more accurate representation of narrow peaks. Selectable data acquisition rates for your application help reduce file size. A 20-bit A/D converter provides finer digital resolution of baseline noise, reducing quantization error.
An innovative beam shaperstacked optic fibers that have collected emergent light from the flow cellreshapes the light into an efficient narrow vertical beam before it is transmitted to the diffraction grating. All light is collected, unlike competitive mechanical "slit" optics. The beam shaper delivers 1.2 nm digital resolution using the 512 element array across the 190-800 nm spectral range. Precision The Model 6000 diagnostics permit real time monitoring of lamp intensity and usage. A built-in cuvette filled with holmium-oxide solution and diagnostics software verify wavelength accuracy during validation testing and enable electronic recalibration. The unique validation program not only verifies wavelength accuracy, but also linearity, noise, and drift. Validation is at your fingertips. Printed reports provide evidence of the Model 6000 s performance. |
Sensitivity The LightPipe flow cell5 times the length for 5 times the signal.
Performance Innovative optical design for better spectra and greater application flexibility.
Precision Built-in calibration procedures for confidence in the data.
Model 6000 Dual-Source Lamps Combined,
they cover the full UV/Vis range.
|