The Series 2500 Protein LC System, built around the Series 2500
integrated quaternary low-pressure mixing pump, is a compact HPLC
package that gives you the capability to perform protein separations and
routine analytical chromatography applications for a fraction of the
cost of other systems.
The Model V520 UV/VIS detector gives you the sensitivity and flexibility
today’s separations require. The fixed wavelength 254/280nm detector is
an economical option. The system is available with Stainless steel or
PEEK fluid paths. The Series 2500 Gradient System can be operated in
stand-alone mode or through PC software. The Series 2500 pump stores up
to 10 methods and allows interfacing with autosamplers and data systems
for system automation.
Data collection can be achieved by adding a chart recorder or PeakSimple
data acquisition software.
The Series 2500 pump
can store up to ten gradient methods. Each method may be up to 50 steps
long with a total run time of 999.99 minutes. Each step can be
programmed with the solvent composition, flow rate, and external events
to provide extended HPLC system control and automation capability.
Methods may be automatically repeated up to 99 times, and linked to
occur in a user-programmed sequence. The dual piston 12mL pump in the
Model 2500 provides compact and fully integrated modern stepper motor
technology combined with years of industry experience to create a high
performance system at an exceptional value.
Pump performance is
optimized with a vacuum degasser. For preparative applications where
high flow rates are required, order the 100 mL version of the Model 2500
pump.
PeakSimple Data Acquisition
-
Collect data using
single-channel or 4-channel PeakSimple Data package.
-
Easy to learn,
easy to use software-produce results almost immediately.
-
Simple user
interface features for
manual
integration, baseline
subtraction
and data smoothing,
multi-level
calibration, overlaying
chromatograms, data logger mode.
-
Easy to connect
interface box hooks up to most standard Pentium PCs running Windows.
-
Built-in timing
mechanism to work
with
Windows applications (Excel,
Word).
UV-Vis Detector
The Model
V520 is one of the most versatile, reliable, and sensitive UV-Vis
absorbance monitors available. The V520 uses state-of-the-art photodiode
design with complementary high-photon throughput optics. With a variety
of sample cell designs, this detector is capable of meeting virtually
every application requirement in the laboratory.
-
The V520
Variable UV-Vis detector is capable of working from 190 to 400 nm with
optical range extension into the NIR (940 nm) with broad bandpass,
using only the D2 lamp.
-
The V520
offers one of the lowest noise and drift specifications in the
industry.
-
The V520
can be modified in the field without special alignment tools to
accommodate many different sample cells. Available sample cells
include analytical, microbore and preparative. For preparative protein
separations, use either the Prep variable path length (0-4 mm) flow
cell or the fixed pathlength (1 mm) cell.
-
An
economical detector option is the fixed wavelength 254/280nm Model
F110 detector. The same flow cell options are available with this
version.
Add an autosampler and fraction collector for automation
Variable-volume Autosampler
The
variable-volume autosampler provides outstanding performance and maximum
flexibility in a variable-volume, LC sample processing system. The
standard unit provides 120-vial capacity, multiple injection modes,
random vial access, reuse of calibration standards, and nonvolatile
storage of 4 complete methods.
Inert Autosampler
The inert
autosampler provides all the features of the variable-volume autosampler,
but in a metal-free, inert version. This autosampler is ideally suited
for biological applications requiring metalfree operation or
applications that use corrosive solvents or buffers.
FC Jr. Fraction Collector
FC Jr. holds microcentrifuge tubes to 250 mL Erlenmeyers, and easily
stretches to hold tubes up to 150 mm tall. FC Jr. gives you great
capacity in minimal space. FC racks are available for almost any tube or
vial, and even 96-well microplates. When you need increased amounts of
purified product, FC Jr. lets you collect unlimited volumes in off-deck
containers with a funnel rack.
Standard Features of FC Jr.
-
Collect peaks of interest using any combination of slope, level, and
time windows.
-
Optional interface cable for connection to detector – used for
slope/level sensing, event marking, start and advance inputs.
-
Collect uniform fractions by time, drop count, or pumped volume.
|
 |
Gradient Pump
|
Flow Rate |
0.01 - 12.00 mL/min. or 0.1-100 mL/min. |
|
Pressure |
Stainless Steel:
0 –6,000 psi;
PEEK:
0 – 5,000 psi
Stainless Steel/PEEK:
0-500 psi (100 mL version) |
|
Pulsation |
±
0.5% @ 1 mL/min and 1,000 psi |
|
Flow Accuracy |
±
2% |
|
Flow Precision |
0.2% RSD |
|
Dimensions |
7.5" H x 10.375" W x 17.5" D (19 x 26 x 44 cm) |
|
Weight |
32 lbs. (14.5 kg) |
|
Standard Controls:
•
RS-232 Serial Com Port for Complete Control & Status Monitoring
•
Run/stop Inputs (5 volt TTL type)
•
Remote 0 - 10 volt & remote 0 –10 kHz Flow Rate Control Input
•
Pressure monitoring (via transducer) with user selected upper/lower
pressure limits
Standard Pump Features:
•
Self Flushing Pump Head and Prime Purge Valve
•
Stainless Steel or PEEK Fluid Path
•
Autoprime™ one button toggles flow rate to maximum for rapid solvent
change
•
Electronic pressure transducer (isolated through pulse damper)
•
Pulse Damper for Reduced Pulsation
•
3-year warranty
Gradient Features:
•
High-contrast backlit four-line by 20 character LCD display
•
4 contact closure relay outputs. Normally open contacts
•
Four RS-232 ports for high pressure gradient pump control
•
RS-232 port for link to PC for file downloading
•
4 LED indicators provide control and programming status
•
10 method file capacity, up to 50 event lines per method
•
Choice of low pressure or high-pressure gradient forming modes
•
Concave, convex or linear gradient profiles. 10 curve choices for
concave/convex
•
Method file may be repeated up to 100 times
•
Duration of method may be up to 999.9 minutes
•
Each method file contains a 2-line description field
•
Remote start and stop inputs TTL or contact closure compatible
(active low)
•
Remote Continue (Inject) input to release a holding method
•
Pump gradient percent range: 0-100% in 0.1% increments. Percents B,
C, D programmable; Percent A automatically adjusted
•
Programmable upper/lower pump pressure limits settable per pump
operating range |
|
Model V520 Detector: |
|
|
Light source: |
Deuterium (typical lifetime of >2000 hrs.), easily changed,
prealigned. |
|
Optical design: |
Prism monochromator (patented) with dual beam silicon photodiodes;
wavelength selection from 190-940 nm |
|
Wavelength selection |
190 nm to 940 nm in increments of 1 nm; user selected from front
panel via push button input, or selected from computer via RS-232
input/output |
|
Wavelength accuracy: |
< ± 2 nm |
|
Wavelength precision: |
< ± 0.2 nm |
|
Wavelength bandpass: |
<8.0 nm (typical) at half-height (at 250 nm) |
|
Noise and Drift: |
< ± 1 x 10-5
AU/10 mm pathlength (over 30 sec period peak to peak, 1.0 sec rise
time); < ± 1 x 10-4
AU/10 mm pathlength (over 30 min period peak to peak, 1.0 sec rise
time) with standard sample cell at constant temperature |
|
Input/Output connections: |
RS-232 computer I/O; autoinjection input (event or run); autozero
input; one analog integrator or chart recorder output, (voltage
range default Input/Output connections:1.0 V/AU); selectable analog
range outputs of 4.0, 2.0, 1.0, 0.5, 0.2, 0.1, 0.05, 0.02, 0.01,
0.005, 0.002, 0.001, 0.0005 AU/V with total voltage range of ± 4 V
at any scale |
|
Displays: |
Absorbance (5 digits LED); wavelength (3 digits LED); analog output
range (momentarily from absorbance display by pressing range
switch); reference light level; sample light level |
|
Sample cell: |
Standard HPLC flow cell with 10 mm pathlength, total dead volume of
18.0 µL (illuminated volume). |
|
Injector valve |
Stainless steel |
PEEK |
|
Maximum operating pressure: |
35 MPa |
34 MPa |
|
Capillary connection: |
1/16" OD UNF 10 standard thread |
1/16” Rheodyne fittings |
|
Injection loop supplied: |
20 µL |
20 µL |
|
Materials in contact with mobile phase |
Stainless steel, Vespel |
PEEK, alumina ceramic, inert polymer |
act system re |